The AT89C51 has two 16-bit Timer/Counter registers: Timer 0 and Timer 1. The
AT89C52 has these two Timer/Counters, and in addition Timer 2. All three can be
configured to operate either as Timers or event Counters. As a Timer, the
register is incremented every machine cycle. Thus, the register counts machine
cycles. Since a machine cycle consists of 12 oscillator periods, the count rate
is 1/12 of the oscillator frequency. As a Counter, the register is incremented
in response to a 1 to- 0 transition at its corresponding external input pin, T0,
T1, or (in the AT89C52) T2. The external input is sampled during S5P2 of every
machine cycle. When the samples show a high in one cycle and a low in the next
cycle, the
count is incremented. The new count value appears in the register during S3P1 of
the cycle following the one in which the transition was detected. Since 2
machine cycles (24 oscillator periods) are required to recognize a l-to-0
transition, the maximum count rate is 1/24 of the oscillator frequency. There
are no restrictions on the duty cycle of the external input signal, but it
should be held for at least one full machine cycle to ensure that a given level
is sampled at least once before it changes. In addition to the Timer or Counter
functions, Timer 0 and Timer 1 have four operating modes: (13 bit timer, 16 bit
timer, 8 bit auto-reload, split timer). Timer 2 in the AT89C52 has three modes
of operation: Capture, Auto-Reload, and baud rate generator.
Timer 0 and Timer
1
Timer/Counters 1 and
0 are present in both the AT89C51 and AT89C52. The Timer or Counter function is
selected by control bits C/T in the Special Function Register TMOD (Figure 6).
These two Timer/Counters have four operating modes, which are selected by bit
pairs (M1, M0) in TMOD. Modes 0, 1, and 2 are the same for both Timer/Counters,
but Mode 3 is different. The four modes are described in the following sections.